{"title":"350kpa","description":"\u003cp\u003e350kpa\u003c\/p\u003e","products":[{"product_id":"fm350-lead-free-350kpa-1-2-genuine-apex-filtamate-pressure-limiting-valve","title":"FM350 LEAD FREE, 350kPa 1\/2\" Genuine APEX Filtamate Pressure Limiting Valve","description":"\u003cdiv class=\"short-description\"\u003e\n\u003cp\u003eFM350 LEAD FREE, 350kPa 1\/2″ Genuine APEX Filtamate Pressure Limiting Valve\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch1 align=\"center\"\u003e\u003cimg class=\"entered lazyloaded\" src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/WM_AQUABLUEH2O.png\" alt=\"\" width=\"180\" height=\"181\"\u003e\u003c\/h1\u003e\n\u003ch2 align=\"center\"\u003eAS1357.2 \u0026amp; AS\/NZS2845.1\u003c\/h2\u003e\n\u003ch2 align=\"center\"\u003eLic.WMKA2596\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFM350    Filtamate® - Pressure Limiting Valve\u003c\/p\u003e\n\u003cp\u003eHigh pressure systems to protect downstream components e.g. water filters, drink dispensers, ice makers, coffee machines and reverse osmosis machines. Mobile homes and caravans where a connection is available to mains water.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"top\" width=\"780\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" width=\"780\"\u003e\n\u003cul\u003e\n\u003cli\u003eFlow rate: 14 LPM @ 700Kpa (100psi) inlet pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"top\" width=\"539\"\u003eFeatures\/Benefits\n\u003cul\u003e\n\u003cli\u003ePrecision machined from high quality NZ brass\u003c\/li\u003e\n\u003cli\u003eIntegral dual check valves help prevent backflow\u003c\/li\u003e\n\u003cli\u003eIntegral line strainer protects device and eliminates need for additional strainer to be fitted upstream.\u003c\/li\u003e\n\u003cli\u003eFiltamate resists water hammer and limits water pressure to filters thus avoiding costly water damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eStandards\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with NZ Building Code G12 (2001)\u003c\/li\u003e\n\u003cli\u003eComplies with NZS 4608:1992\u003c\/li\u003e\n\u003cli\u003eAustralian Watermark Approval AS1357.2 Lic. 02596\u003c\/li\u003e\n\u003cli\u003eAustralian Watermark Approval AS2845.1 Lic. 21876 (FM, FM 1\/2 only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#eeeeee\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFM\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eLength\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eDual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cdiv class=\"ProductDescriptionContainer\"\u003e\n\u003cp\u003eApex Filtamate Brass pressure limiting valve with daul check non return. 1\/2\" Bsp female inlet and 1\/4\" Bsp female outlet. Protects water filter units by limiting water pressure.\u003c\/p\u003e\n\u003cp\u003eReduces pressure to 350 Kpa\u003c\/p\u003e\n\u003cp\u003eIdeal for R\/O units, Fridges, Ice Makers and Coffee Makers. Resists water hammer.\u003c\/p\u003e\n\u003cp\u003eLimits pressure and Stops back flow.\u003c\/p\u003e\n\u003cp\u003e95mm x 30mm Made in New Zealand.\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"heading\"\u003eFilta\u003cem\u003eMate\u003c\/em\u003e® - Pressure Limiting Valves\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" width=\"780\"\u003e\u003cimg src=\"https:\/\/www.apexvalves.co.nz\/images\/pixel.gif\" alt=\"\" width=\"1\" height=\"20\" border=\"0\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"top\" width=\"539\"\u003e\n\u003cspan class=\"caption\"\u003eApplication\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eHigh pressure systems to protect downstream components, e.g. Water filters, drink dispensers, ice makers, coffee machines and reverse osmosis machines.\u003c\/li\u003e\n\u003cli\u003eMobile homes and caravans where a connection is available to mains water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\"\u003eFeatures\/Benefits\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFM \u0026amp; FM 1\/2 are precision machined from high quality NZ brass. FM valve is nickel plated.\u003c\/li\u003e\n\u003cli\u003eIntegral dual check valves help prevent backflow (Not included all models - see specifications and product codes below).\u003c\/li\u003e\n\u003cli\u003eIntegral line strainer protects device and eliminates need for additional strainer to be fitted upstream. (Not included all models - see specifications and product codes below).\u003c\/li\u003e\n\u003cli\u003eFilta\u003cem\u003eMate\u003c\/em\u003e resists water hammer and limits water pressure to filters thus avoiding costly water damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\"\u003eStandards\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with NZ Building Code G12 (2001)\u003c\/li\u003e\n\u003cli\u003eComplies with NZS 4608:1992\u003c\/li\u003e\n\u003cli\u003eAustralian Watermark Approval AS1357.2 Lic. 02596\u003c\/li\u003e\n\u003cli\u003eAustralian Watermark Approval AS2845.1 Lic. 21876 (FM, FM 1\/2 only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\"\u003eSpecifications\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFM\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e8mm 1\/4\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eLength\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e97mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eDual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFM 1\/2\u003c\/td\u003e\n\u003ctd width=\"24%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eDual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMP\u003c\/td\u003e\n\u003ctd width=\"24%\"\u003eInlet\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e1\/4\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eOutlet\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e1\/4\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eDual (Excludes FMP NZ) - [Available in Imperial pressure ratings without Check Valve - see \u003ca class=\"link\" href=\"https:\/\/www.apexvalves.co.nz\/plumbing\/filtamate\/#imperial\"\u003eImperial Product Codes\u003c\/a\u003e below].\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMP 3\/8\u003c\/td\u003e\n\u003ctd width=\"24%\"\u003eInlet\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e3\/8\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eOutlet\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e3\/8\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e110mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eDual [Available in Imperial pressure ratings without Check Valve - see \u003ca class=\"link\" href=\"https:\/\/www.apexvalves.co.nz\/plumbing\/filtamate\/#imperial\"\u003eImperial Product Codes\u003c\/a\u003e below].\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMBP\u003c\/td\u003e\n\u003ctd width=\"24%\"\u003eInlet\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eOutlet\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e1\/4\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eDual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFM12\u003c\/td\u003e\n\u003ctd width=\"24%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"24%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e12mm John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMSC12\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e12mm John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eLength:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e107mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" valign=\"top\" width=\"30%\"\u003eFlow rate:\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"70%\"\u003e14 L\/min [4 USgpm] at 700 kPa [100psi] inlet pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" valign=\"top\" width=\"30%\"\u003ePressure ratio:\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"70%\"\u003e10:1 (for every 10 kPa [1.5psi] increase in inlet pressure above 1000 kPa [150psi], the outlet pressure will increase by 1 kPa [0.145psi]).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" valign=\"top\" width=\"30%\"\u003eOutlet pressures:\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"70%\"\u003e350 and 600 kPa [50, 60 and 85psi] +\/- 10% @ 1000 kPa [150psi] inlet pressure (Contact Apex Valves for additional pressures available).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" valign=\"top\" width=\"30%\"\u003eMaximum inlet pressure:\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"70%\"\u003e1600 kPa [230psi]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" valign=\"top\" width=\"30%\"\u003eMaximum temperature:\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"70%\"\u003e40˚C [105˚F]; 60˚C [140˚] for FM and FM 1\/2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" valign=\"top\" width=\"30%\"\u003eMinimum temperature:\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"70%\"\u003e1˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eFMP supplied with fixing clip and screw.\u003c\/li\u003e\n\u003cli\u003eFM DR (Dezincification Resistant) brass.\u003c\/li\u003e\n\u003cli\u003eFMP Acetyl plastic.\u003c\/li\u003e\n\u003cli\u003eFMBP DR brass inlet, acetyl plastic outlet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\"\u003eInstallation\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstallation must be carried out by a Qualified Person.\u003c\/li\u003e\n\u003cli\u003eAll pipe work must be flushed prior to installation.\u003c\/li\u003e\n\u003cli\u003eDo NOT apply heat near valve during installation.\u003c\/li\u003e\n\u003cli\u003eMust be fitted downstream of approved isolating valves.\u003c\/li\u003e\n\u003cli\u003eMust be installed in the direction as indicated by the flow arrow.\u003c\/li\u003e\n\u003cli\u003eMust be protected by a line strainer (See specifications and product codes for valves with integral line strainer).\u003c\/li\u003e\n\u003cli\u003eMust be installed according to local regulations.\u003c\/li\u003e\n\u003cli\u003eMay be fitted in any orientation.\u003c\/li\u003e\n\u003cli\u003eWarranty is limited to any fault found in a valve due to poor workmanship or materials that is returned to Apex Valves Ltd within 1 year from the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eIf thermal expansion (due to heating, cooling) or back pressure can occur downstream, an expansion valve must be fitted to relieve the excessive pressure build up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\"\u003eServicing\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Filta\u003cem\u003eMate\u003c\/em\u003e valve opens and closes automatically every time water is drawn through it. As it is a mechanical device we recommend that it is replaced every 5 years or sooner in high usage installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/Filtamate+Pressure+Limiting+Valves-1.jpg\" alt=\"\" width=\"100%\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ProductDescriptionContainer\"\u003e\u003cimg src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/Filtamate+Pressure+Limiting+Valves-2.jpg\" alt=\"\" width=\"100%\"\u003e\u003c\/div\u003e\n","brand":"Aqua Blue Filters","offers":[{"title":"Default Title","offer_id":67766976348387,"sku":"FM350 1\/2\" LEAD FREE","price":76.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1249\/4307\/files\/fm350-lead-free-350kpa-12-genuine-apex-filtamate-pressure-limiting-valve.jpg?v=1792622915"},{"product_id":"fmsc12-350-lead-free-350kpa-1-2-genuine-apex-filtamate-pressure-limiting-valve","title":"FMSC12-350 LEAD FREE, 350kPa 1\/2\" Genuine APEX Filtamate Pressure Limiting Valve","description":"\u003cdiv class=\"short-description\"\u003e\n\u003cp\u003eFMSC12-350 LEAD FREE, 350kPa 1\/2″ Genuine APEX Filtamate Pressure Limiting Valve\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch1 align=\"center\"\u003e\u003cimg class=\"entered lazyloaded\" src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/WM_AQUABLUEH2O.png\" alt=\"\" width=\"180\" height=\"181\"\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2 align=\"center\"\u003eAS1357.2 \u0026amp; AS\/NZS2845.1\u003c\/h2\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2 align=\"center\"\u003eLic.WMKA2596\u003c\/h2\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold;\"\u003eAPEX Filtamate Caravan Pressure Limiting Valve FMSC12-350\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold;\"\u003eCaravan Pressure Limiting Valve 350KPA Quality Brass 1\/2\" F to 12mm Tube (18-10)\u003cbr\u003e\n\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold;\"\u003e\u003cbr\u003e\nSpecifications\u003cbr\u003e\n\u003c\/span\u003e\u003cspan class=\"caption\" style=\"color: #333333;\"\u003eInlet: 15mm, 1\/2\" BSP (female)\u003c\/span\u003e\u003cspan class=\"caption\" style=\"color: #333333;\"\u003e\u003cbr\u003e\nOutlet: 12mm John Guest connector\u003cbr\u003e\nLength: 107mm\u003cbr\u003e\nFlow rate: 15 L\/min at 700 kPa [100 P.S.I.] inlet pressure\u003cbr\u003e\nPressure ratio: 10:1 (for every 10 kPa [1.5 P.S.I.] increase in inlet pressure above 1000kPa [150 P.S.I.], the outlet pressure will increase by 1 kPa [0.145 P.S.I.).\u003cbr\u003e\nOutlet pressures: 350 kPa [50 P.S.I.]\u003cbr\u003e\nMaximum inlet pressure: 2000 kPa [290 P.S.I.]\u003cbr\u003e\nMaximum temperature: 60°C\u003cbr\u003e\n\u003c\/span\u003e\u003cspan class=\"caption\" style=\"color: #333333;\"\u003e Minimum temperature: 1°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold;\"\u003eInstallation\u003cbr\u003e\n\u003c\/span\u003e\u003cspan class=\"caption\" style=\"color: #333333;\"\u003eInstallation must be carried out by a Qualified Person.\u003c\/span\u003e\u003cspan class=\"caption\" style=\"color: #333333;\"\u003e\u003cbr\u003e\nAll pipe work must be flushed prior to installation.\u003cbr\u003e\nMust be protected by a line strainer (integral with FM).\u003cbr\u003e\nDo NOT apply heat near valve during installation.\u003cbr\u003e\nMay be fitted in any orientation.\u003cbr\u003e\nMust be fitted downstream of approved isolating valves.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr style=\"color: #333333; font-family: 'Arial Black'; font-size: medium;\"\u003e\u003cbr style=\"color: #333333; font-family: 'Arial Black'; font-size: medium;\"\u003e\u003cbr style=\"color: #333333; font-family: 'Arial Black'; font-size: medium;\"\u003e\u003cbr style=\"color: #333333; font-family: 'Arial Black'; font-size: medium;\"\u003e\u003cspan class=\"heading\" style=\"font-family: 'Arial Black'; font-size: medium; font-style: normal; color: #cc0020; font-weight: bold; background-color: #ffffff;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eFilta\u003c\/span\u003e\u003cspan style=\"color: #008000;\"\u003e\u003cem\u003eMate\u003c\/em\u003e\u003c\/span\u003e® - Pressure Limiting Valves\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"font-family: 'Arial Black'; background-color: #ffffff; width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" align=\"left\" valign=\"top\" width=\"780\"\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" colspan=\"5\" width=\"780\"\u003e\u003cimg src=\"http:\/\/www.apexvalves.co.nz\/images\/pixel.gif\" alt=\"\" width=\"1\" height=\"20\" border=\"0\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" align=\"left\" valign=\"top\" width=\"539\"\u003e\n\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold;\"\u003eApplication\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eHigh pressure systems to protect downstream components, e.g. Water filters, drink dispensers, ice makers, coffee machines and reverse osmosis machines.\u003c\/li\u003e\n\u003cli\u003eMobile homes and caravans where a connection is available to mains water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold;\"\u003eFeatures\/Benefits\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFM \u0026amp; FM 1\/2 are precision machined from high quality NZ brass. FM valve is nickel plated.\u003c\/li\u003e\n\u003cli\u003eIntegral dual check valves help prevent backflow (Not included all models - see specifications and product codes below).\u003c\/li\u003e\n\u003cli\u003eIntegral line strainer protects device and eliminates need for additional strainer to be fitted upstream. (Not included all models - see specifications and product codes below).\u003c\/li\u003e\n\u003cli\u003eFilta\u003cem\u003eMate\u003c\/em\u003e resists water hammer and limits water pressure to filters thus avoiding costly water damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"100%\"\u003e\n\u003ctable style=\"width: 533px;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" rowspan=\"2\" width=\"122\"\u003e\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" colspan=\"2\" width=\"411\"\u003eFilta\u003cem\u003eMate\u003c\/em\u003e® Pressure Limiting Valves.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"261\"\u003e\u003cspan style=\"color: #cc0020;\"\u003e Run-time: 1:15 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" align=\"center\" width=\"150\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold;\"\u003eStandards\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with NZ Building Code G12 (2001)\u003c\/li\u003e\n\u003cli\u003eComplies with NZS 4608:1992\u003c\/li\u003e\n\u003cli\u003eAustralian Watermark Approval AS1357.2 Lic. 02596\u003c\/li\u003e\n\u003cli\u003eAustralian Watermark Approval AS2845.1 Lic. 21876 (FM, FM 1\/2 only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold;\"\u003eSpecifications\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"margin-left: 0in;\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFM\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003e8mm 1\/4\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003e97mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003eDual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"margin-left: 0in;\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFM 1\/2\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"24%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"61%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"24%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"61%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"61%\"\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003eDual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"margin-left: 0in;\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMP\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"24%\"\u003eInlet\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"61%\"\u003e1\/4\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"24%\"\u003eOutlet\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"61%\"\u003e1\/4\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"61%\"\u003e98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" valign=\"top\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003eDual (Excludes FMP NZ) - [Available in Imperial pressure ratings without Check Valve - see \u003ca class=\"link\" style=\"color: #cc0020; font-weight: bold; text-decoration: none;\" href=\"http:\/\/www.apexvalves.co.nz\/plumbing\/filtamate\/#imperial\"\u003eImperial Product Codes\u003c\/a\u003e below].\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"margin-left: 0in;\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMP 3\/8\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"24%\"\u003eInlet\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"61%\"\u003e3\/8\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"24%\"\u003eOutlet\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"61%\"\u003e3\/8\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"61%\"\u003e110mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003eDual [Available in Imperial pressure ratings without Check Valve - see \u003ca class=\"link\" style=\"color: #cc0020; font-weight: bold; text-decoration: none;\" href=\"http:\/\/www.apexvalves.co.nz\/plumbing\/filtamate\/#imperial\"\u003eImperial Product Codes\u003c\/a\u003e below].\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"margin-left: 0in;\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMBP\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"24%\"\u003eInlet\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"61%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"24%\"\u003eOutlet\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"61%\"\u003e1\/4\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"61%\"\u003e98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003eDual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"margin-left: 0in;\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFM12\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"24%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" valign=\"top\" width=\"24%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"61%\"\u003e12mm John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"61%\"\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"margin-left: 0in;\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMSC12\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003e12mm John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eLength:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003e107mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" width=\"60%\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"margin-left: 0in;\" valign=\"top\" width=\"30%\"\u003eFlow rate:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" valign=\"top\" width=\"70%\"\u003e14 L\/min [4 USgpm] at 700 kPa [100psi] inlet pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"margin-left: 0in;\" valign=\"top\" width=\"30%\"\u003ePressure ratio:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" valign=\"top\" width=\"70%\"\u003e10:1 (for every 10 kPa [1.5psi] increase in inlet pressure above 1000 kPa [150psi], the outlet pressure will increase by 1 kPa [0.145psi]).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"margin-left: 0in;\" valign=\"top\" width=\"30%\"\u003eOutlet pressures:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" valign=\"top\" width=\"70%\"\u003e350 and 600 kPa [50, 60 and 85psi] +\/- 10% @ 1000 kPa [150psi] inlet pressure (Contact Apex Valves for additional pressures available).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"margin-left: 0in;\" valign=\"top\" width=\"30%\"\u003eMaximum inlet pressure:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" valign=\"top\" width=\"70%\"\u003e1600 kPa [230psi]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"margin-left: 0in;\" valign=\"top\" width=\"30%\"\u003eMaximum temperature:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" valign=\"top\" width=\"70%\"\u003e40˚C [105˚F]; 60˚C [140˚] for FM and FM 1\/2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"margin-left: 0in;\" valign=\"top\" width=\"30%\"\u003eMinimum temperature:\u003c\/td\u003e\n\u003ctd style=\"margin-left: 0in;\" valign=\"top\" width=\"70%\"\u003e1˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eFMP supplied with fixing clip and screw.\u003c\/li\u003e\n\u003cli\u003eFM DR (Dezincification Resistant) brass.\u003c\/li\u003e\n\u003cli\u003eFMP Acetyl plastic.\u003c\/li\u003e\n\u003cli\u003eFMBP DR brass inlet, acetyl plastic outlet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold;\"\u003eInstallation\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstallation must be carried out by a Qualified Person.\u003c\/li\u003e\n\u003cli\u003eAll pipe work must be flushed prior to installation.\u003c\/li\u003e\n\u003cli\u003eDo NOT apply heat near valve during installation.\u003c\/li\u003e\n\u003cli\u003eMust be fitted downstream of approved isolating valves.\u003c\/li\u003e\n\u003cli\u003eMust be installed in the direction as indicated by the flow arrow.\u003c\/li\u003e\n\u003cli\u003eMust be protected by a line strainer (See specifications and product codes for valves with integral line strainer).\u003c\/li\u003e\n\u003cli\u003eMust be installed according to local regulations.\u003c\/li\u003e\n\u003cli\u003eMay be fitted in any orientation.\u003c\/li\u003e\n\u003cli\u003eWarranty is limited to any fault found in a valve due to poor workmanship or materials that is returned to Apex Valves Ltd within 1 year from the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eIf thermal expansion (due to heating, cooling) or back pressure can occur downstream, an expansion valve must be fitted to relieve the excessive pressure build up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold;\"\u003eServicing\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Filta\u003cem\u003eMate\u003c\/em\u003e valve opens and closes automatically every time water is drawn through it. As it is a mechanical device we recommend that it is replaced every 5 years or sooner in high usage installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/Filtamate+Pressure+Limiting+Valves-1.jpg\" alt=\"\" width=\"100%\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/Filtamate+Pressure+Limiting+Valves-2.jpg\" alt=\"\" width=\"100%\"\u003e\u003c\/p\u003e\n","brand":"Aqua Blue Filters","offers":[{"title":"Default Title","offer_id":67766976381155,"sku":"FMSC 12-350 1\/2\"","price":69.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1249\/4307\/files\/fmsc12-350-lead-free-350kpa-12-genuine-apex-filtamate-pressure-limiting-valve.jpg?v=1792622918"},{"product_id":"fm350-350kpa-1-2-inlet-1-4-outlet-genuine-apex-filtamate-pressure-limiting-valve","title":"FM350, 350kPa 1\/2\" inlet - 1\/4” outlet Genuine APEX Filtamate Pressure Limiting Valve","description":"\u003cdiv class=\"short-description\"\u003e\n\u003cp\u003eFM350, 350kPa 1\/2″ inlet – 1\/4” outlet Genuine APEX Filtamate Pressure Limiting Valve\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch1 align=\"center\"\u003e\u003cimg class=\"entered lazyloaded\" src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/WM_AQUABLUEH2O.png\" alt=\"\" width=\"180\" height=\"181\"\u003e\u003c\/h1\u003e\n\u003ch2 align=\"center\"\u003eAS1357.2 \u0026amp; AS\/NZS2845.1\u003c\/h2\u003e\n\u003ch2 align=\"center\"\u003eLic.WMKA2596\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin: .5em 0px; font-size: 13px; color: #545454; background-color: #fafefe;\"\u003e\u003cspan style=\"font-family: Arial; font-size: 10pt;\"\u003eFM350    Filtamate® - Pressure Limiting Valve\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: .5em 0px; font-size: 13px; color: #545454; background-color: #fafefe;\"\u003e\u003cspan style=\"font-family: Arial; font-size: 10pt;\"\u003eHigh pressure systems to protect downstream components e.g. water filters, drink dispensers, ice makers, coffee machines and reverse osmosis machines. Mobile homes and caravans where a connection is available to mains water.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 style=\"font-family: 'Times New Roman'; text-transform: none; margin-bottom: 5px; padding-top: 0px; color: #034285; background-color: #ffffff;\"\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"top\" width=\"780\"\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" width=\"780\"\u003e\n\u003cul style=\"color: #404040; margin-top: 1em; margin-bottom: 1em; margin-left: 2em; list-style-type: none;\"\u003e\n\u003cli style=\"margin-top: .2em; margin-bottom: .2em; padding-left: 9px; line-height: 1em; background-image: url('%27%27%27%27%27%27%27%27%27http%3A\/\/www.pureas.co.nz\/images\/template\/layouts\/tpl%27163\/images\/postbullets.png%27%27%27%27%27%27%27%27%27');\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eFlow rate: 14 LPM @ 700Kpa (100psi) inlet pressure\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"top\" width=\"539\"\u003e\n\u003cp style=\"margin: .5em 0px; font-size: 13px;\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eFeatures\/Benefits\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"color: #404040; margin-top: 1em; margin-bottom: 1em; margin-left: 2em; list-style-type: none;\"\u003e\n\u003cli style=\"margin-top: .2em; margin-bottom: .2em; padding-left: 9px; line-height: 1em; background-image: url('%27%27%27%27%27%27%27%27%27http%3A\/\/www.pureas.co.nz\/images\/template\/layouts\/tpl%27163\/images\/postbullets.png%27%27%27%27%27%27%27%27%27');\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003ePrecision machined from high quality NZ brass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: .2em; margin-bottom: .2em; padding-left: 9px; line-height: 1em; background-image: url('%27%27%27%27%27%27%27%27%27http%3A\/\/www.pureas.co.nz\/images\/template\/layouts\/tpl%27163\/images\/postbullets.png%27%27%27%27%27%27%27%27%27');\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eIntegral dual check valves help prevent backflow\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: .2em; margin-bottom: .2em; padding-left: 9px; line-height: 1em; background-image: url('%27%27%27%27%27%27%27%27%27http%3A\/\/www.pureas.co.nz\/images\/template\/layouts\/tpl%27163\/images\/postbullets.png%27%27%27%27%27%27%27%27%27');\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eIntegral line strainer protects device and eliminates need for additional strainer to be fitted upstream.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: .2em; margin-bottom: .2em; padding-left: 9px; line-height: 1em; background-image: url('%27%27%27%27%27%27%27%27%27http%3A\/\/www.pureas.co.nz\/images\/template\/layouts\/tpl%27163\/images\/postbullets.png%27%27%27%27%27%27%27%27%27');\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eFiltamate resists water hammer and limits water pressure to filters thus avoiding costly water damage.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 10pt;\"\u003eStandards\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"color: #404040; margin-top: 1em; margin-bottom: 1em; margin-left: 2em; list-style-type: none;\"\u003e\n\u003cli style=\"margin-top: .2em; margin-bottom: .2em; padding-left: 9px; line-height: 1em; background-image: url('%27%27%27%27%27%27%27%27%27http%3A\/\/www.pureas.co.nz\/images\/template\/layouts\/tpl%27163\/images\/postbullets.png%27%27%27%27%27%27%27%27%27');\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eComplies with NZ Building Code G12 (2001)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: .2em; margin-bottom: .2em; padding-left: 9px; line-height: 1em; background-image: url('%27%27%27%27%27%27%27%27%27http%3A\/\/www.pureas.co.nz\/images\/template\/layouts\/tpl%27163\/images\/postbullets.png%27%27%27%27%27%27%27%27%27');\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eComplies with NZS 4608:1992\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: .2em; margin-bottom: .2em; padding-left: 9px; line-height: 1em; background-image: url('%27%27%27%27%27%27%27%27%27http%3A\/\/www.pureas.co.nz\/images\/template\/layouts\/tpl%27163\/images\/postbullets.png%27%27%27%27%27%27%27%27%27');\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eAustralian Watermark Approval AS1357.2 Lic. 02596\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"margin-top: .2em; margin-bottom: .2em; padding-left: 9px; line-height: 1em; background-image: url('%27%27%27%27%27%27%27%27%27http%3A\/\/www.pureas.co.nz\/images\/template\/layouts\/tpl%27163\/images\/postbullets.png%27%27%27%27%27%27%27%27%27');\"\u003e\u003cspan style=\"font-size: 10pt;\"\u003eAustralian Watermark Approval AS2845.1 Lic. 21876 (FM, FM 1\/2 only)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"font-family: 'Times New Roman'; text-transform: none; margin-bottom: 5px; padding-top: 0px; color: #034285; background-color: #ffffff;\"\u003e\u003c\/h3\u003e\n\u003ctable style=\"color: #545454; font-size: 13px; border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#eeeeee\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003e\u003cspan style=\"font-family: Arial; font-size: 10pt;\"\u003eFM\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003e\u003cspan style=\"font-family: Arial; font-size: 10pt;\"\u003eInlet:\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\u003cspan style=\"font-family: Arial; font-size: 10pt;\"\u003e15mm, 1\/2\" BSP (female)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003e\u003cspan style=\"font-family: Arial; font-size: 10pt;\"\u003eOutlet:\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\u003cspan style=\"font-family: Arial; font-size: 10pt;\"\u003e8mm, 1\/4\" BSP (female)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003e\u003cspan style=\"font-family: Arial; font-size: 10pt;\"\u003eLength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\u003cspan style=\"font-family: Arial; font-size: 10pt;\"\u003e100mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003e\u003cspan style=\"font-family: Arial; font-size: 10pt;\"\u003eIntegral Line Strainer:\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\u003cspan style=\"font-family: Arial; font-size: 10pt;\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003e\u003cspan style=\"font-family: Arial; font-size: 10pt;\"\u003eCheck Valve:\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e\u003cspan style=\"font-family: Arial; font-size: 10pt;\"\u003eDual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"font-family: 'Times New Roman'; text-transform: none; margin-bottom: 5px; padding-top: 0px; color: #034285; background-color: #ffffff;\"\u003e\u003c\/h3\u003e\n\u003ch3 style=\"font-family: 'Times New Roman'; text-transform: none; margin-bottom: 5px; padding-top: 0px; color: #034285; background-color: #ffffff;\"\u003e\u003cspan style=\"font-family: Arial; font-size: 12pt;\"\u003eProduct Description\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ProductDescriptionContainer\" style=\"font-family: 'Times New Roman'; font-size: medium; font-style: normal; color: #535353; background-color: #ffffff;\"\u003e\n\u003cp style=\"margin: 0px 0px 15px; line-height: 1.3;\"\u003e\u003cspan style=\"font-family: Arial;\"\u003eApex Filtamate Brass pressure limiting valve with daul check non return. 1\/2\" Bsp female inlet and 1\/4\" Bsp female outlet. Protects water filter units by limiting water pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px; line-height: 1.3;\"\u003e\u003cspan style=\"font-family: Arial;\"\u003eReduces pressure to 350 Kpa\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px; line-height: 1.3;\"\u003e\u003cspan style=\"font-family: Arial;\"\u003eIdeal for R\/O units, Fridges, Ice Makers and Coffee Makers. Resists water hammer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px; line-height: 1.3;\"\u003e\u003cspan style=\"font-family: Arial;\"\u003eLimits pressure and Stops back flow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px; line-height: 1.3;\"\u003e\u003cspan style=\"font-family: Arial;\"\u003e95mm x 30mm Made in New Zealand.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px; line-height: 1.3;\"\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan class=\"heading\"\u003eFilta\u003cem\u003eMate\u003c\/em\u003e® - Pressure Limiting Valves\u003c\/span\u003e\u003cbr\u003e\n\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" width=\"780\"\u003e\u003cimg src=\"http:\/\/www.apexvalves.co.nz\/images\/pixel.gif\" alt=\"\" width=\"1\" height=\"20\" border=\"0\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" valign=\"top\" width=\"539\"\u003e\n\u003cspan class=\"caption\"\u003eApplication\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eHigh pressure systems to protect downstream components, e.g. Water filters, drink dispensers, ice makers, coffee machines and reverse osmosis machines.\u003c\/li\u003e\n\u003cli\u003eMobile homes and caravans where a connection is available to mains water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\"\u003eFeatures\/Benefits\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFM \u0026amp; FM 1\/2 are precision machined from high quality NZ brass. FM valve is nickel plated.\u003c\/li\u003e\n\u003cli\u003eIntegral dual check valves help prevent backflow (Not included all models - see specifications and product codes below).\u003c\/li\u003e\n\u003cli\u003eIntegral line strainer protects device and eliminates need for additional strainer to be fitted upstream. (Not included all models - see specifications and product codes below).\u003c\/li\u003e\n\u003cli\u003eFilta\u003cem\u003eMate\u003c\/em\u003e resists water hammer and limits water pressure to filters thus avoiding costly water damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"100%\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" width=\"122\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" width=\"411\"\u003e Filta\u003cem\u003eMate\u003c\/em\u003e® Pressure Limiting Valves.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"261\"\u003e Run-time: 1:15 seconds\u003c\/td\u003e\n\u003ctd align=\"center\" width=\"150\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan class=\"caption\"\u003eStandards\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with NZ Building Code G12 (2001)\u003c\/li\u003e\n\u003cli\u003eComplies with NZS 4608:1992\u003c\/li\u003e\n\u003cli\u003eAustralian Watermark Approval AS1357.2 Lic. 02596\u003c\/li\u003e\n\u003cli\u003eAustralian Watermark Approval AS2845.1 Lic. 21876 (FM, FM 1\/2 only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\"\u003eSpecifications\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFM\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e8mm 1\/4\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eLength\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e97mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eDual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFM 1\/2\u003c\/td\u003e\n\u003ctd width=\"24%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eDual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMP\u003c\/td\u003e\n\u003ctd width=\"24%\"\u003eInlet\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e1\/4\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eOutlet\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e1\/4\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eDual (Excludes FMP NZ) - [Available in Imperial pressure ratings without Check Valve - see \u003ca class=\"link\" href=\"http:\/\/www.apexvalves.co.nz\/plumbing\/filtamate\/#imperial\"\u003eImperial Product Codes\u003c\/a\u003e below].\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMP 3\/8\u003c\/td\u003e\n\u003ctd width=\"24%\"\u003eInlet\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e3\/8\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eOutlet\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e3\/8\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e110mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eDual [Available in Imperial pressure ratings without Check Valve - see \u003ca class=\"link\" href=\"http:\/\/www.apexvalves.co.nz\/plumbing\/filtamate\/#imperial\"\u003eImperial Product Codes\u003c\/a\u003e below].\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMBP\u003c\/td\u003e\n\u003ctd width=\"24%\"\u003eInlet\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eOutlet\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e1\/4\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eDual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFM12\u003c\/td\u003e\n\u003ctd width=\"24%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"24%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e12mm John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd width=\"61%\"\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMSC12\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e12mm John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eLength:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003e107mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd width=\"60%\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" valign=\"top\" width=\"30%\"\u003eFlow rate:\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"70%\"\u003e14 L\/min [4 USgpm] at 700 kPa [100psi] inlet pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" valign=\"top\" width=\"30%\"\u003ePressure ratio:\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"70%\"\u003e10:1 (for every 10 kPa [1.5psi] increase in inlet pressure above 1000 kPa [150psi], the outlet pressure will increase by 1 kPa [0.145psi]).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" valign=\"top\" width=\"30%\"\u003eOutlet pressures:\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"70%\"\u003e350 and 600 kPa [50, 60 and 85psi] +\/- 10% @ 1000 kPa [150psi] inlet pressure (Contact Apex Valves for additional pressures available).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" valign=\"top\" width=\"30%\"\u003eMaximum inlet pressure:\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"70%\"\u003e1600 kPa [230psi]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" valign=\"top\" width=\"30%\"\u003eMaximum temperature:\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"70%\"\u003e40˚C [105˚F]; 60˚C [140˚] for FM and FM 1\/2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" valign=\"top\" width=\"30%\"\u003eMinimum temperature:\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"70%\"\u003e1˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eFMP supplied with fixing clip and screw.\u003c\/li\u003e\n\u003cli\u003eFM DR (Dezincification Resistant) brass.\u003c\/li\u003e\n\u003cli\u003eFMP Acetyl plastic.\u003c\/li\u003e\n\u003cli\u003eFMBP DR brass inlet, acetyl plastic outlet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\"\u003eInstallation\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstallation must be carried out by a Qualified Person.\u003c\/li\u003e\n\u003cli\u003eAll pipe work must be flushed prior to installation.\u003c\/li\u003e\n\u003cli\u003eDo NOT apply heat near valve during installation.\u003c\/li\u003e\n\u003cli\u003eMust be fitted downstream of approved isolating valves.\u003c\/li\u003e\n\u003cli\u003eMust be installed in the direction as indicated by the flow arrow.\u003c\/li\u003e\n\u003cli\u003eMust be protected by a line strainer (See specifications and product codes for valves with integral line strainer).\u003c\/li\u003e\n\u003cli\u003eMust be installed according to local regulations.\u003c\/li\u003e\n\u003cli\u003eMay be fitted in any orientation.\u003c\/li\u003e\n\u003cli\u003eWarranty is limited to any fault found in a valve due to poor workmanship or materials that is returned to Apex Valves Ltd within 1 year from the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eIf thermal expansion (due to heating, cooling) or back pressure can occur downstream, an expansion valve must be fitted to relieve the excessive pressure build up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\"\u003eServicing\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Filta\u003cem\u003eMate\u003c\/em\u003e valve opens and closes automatically every time water is drawn through it. As it is a mechanical device we recommend that it is replaced every 5 years or sooner in high usage installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/Filtamate+Pressure+Limiting+Valves-1.jpg\" alt=\"\" width=\"100%\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ProductDescriptionContainer\" style=\"font-family: 'Times New Roman'; font-size: medium; font-style: normal; color: #535353; background-color: #ffffff;\"\u003e\u003cimg src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/Filtamate+Pressure+Limiting+Valves-2.jpg\" alt=\"\" width=\"100%\"\u003e\u003c\/div\u003e\n","brand":"Aqua Blue Filters","offers":[{"title":"Default Title","offer_id":67766976479459,"sku":"FM350 1\/2\" inlet - 1\/4” outlet","price":76.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1249\/4307\/files\/3-star-premium-function-rail-handset-with-hoseheader-and-wall-bracket-set-sf350-03.png?v=1792622921"},{"product_id":"fmp350-350kpa-1-4-genuine-apex-filtamate-pressure-limiting-valve","title":"FMP350, 350kPa 1\/4\" Genuine APEX Filtamate Pressure Limiting Valve","description":"\u003cdiv class=\"short-description\"\u003e\n\u003cp\u003e\u003cstrong\u003eApex Filtamate\u003c\/strong\u003e 350 KPA Pressure Limiting Valve (PLV) plastic with 1\/4″ tube ports\u003c\/p\u003e\n\u003cp\u003eFMP350 AUSTRALIAN  MADE  GENUINE  PRESSURE LIMITING   VALVE\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApex Filtamate FMP 350 KPA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Limiting Valve (PLV)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlastic with 1\/4″ tube ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cimg class=\"aligncenter\" src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/LOGO_Genuine\/FILTAMATE-LOGO.jpg\" alt=\"FILTAMATE-LOGO.jpg\" width=\"300\" height=\"117\"\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1 align=\"center\"\u003e\u003cimg class=\"entered lazyloaded\" src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/WM_AQUABLUEH2O.png\" alt=\"\" width=\"180\" height=\"181\"\u003e\u003c\/h1\u003e\n\u003ch2 style=\"margin-bottom: 6px; text-align: center;\"\u003eApex Filtamate FMP 350 kPa – Pressure Limiting Valve (PLV)\u003c\/h2\u003e\n\u003cp style=\"margin: 0px 0px 10px; text-align: center;\"\u003e\u003cstrong\u003ePlastic with 1\/4\" tube ports\u003c\/strong\u003e · \u003cstrong\u003eFMP350 AUSTRALIAN MADE\u003c\/strong\u003e · \u003cstrong\u003eGENUINE PRESSURE LIMITING VALVE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"list-style: none; padding-left: 0; margin: 0 0 14px 0;\"\u003e\n\u003cli style=\"text-align: center;\"\u003e\n\u003cstrong\u003eWaterMark:\u003c\/strong\u003e AS1357.2 \u0026amp; AS\/NZS2845.1 — Lic. WMKA2596\u003c\/li\u003e\n\u003cli style=\"text-align: center;\"\u003e\n\u003cstrong\u003eComplies with:\u003c\/strong\u003e NZS 4608:1992\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr style=\"margin: 14px 0;\"\u003e\n\u003ch3 style=\"margin-bottom: 6px;\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFMP350 \/ FMP 350\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA Wells certified \u003cstrong\u003eApex Filtamate\u003c\/strong\u003e Pressure Limiting Valve (PLV) rated to \u003cstrong\u003e350 kPa\u003c\/strong\u003e with \u003cstrong\u003e1\/4\" tube ports\u003c\/strong\u003e is a must for any under bench water filter system.\u003cbr\u003e\nNot having one installed could mean that if you ever did have to claim insurance on damage caused by a burst water filter system may be denied due to the lack of Certified pressure limiting protection installed.\u003c\/p\u003e\n\u003cp\u003eAll complete under bench water filtration systems sold by \u003cstrong\u003eURWater\u003c\/strong\u003e include either a \u003cstrong\u003e350 kPa\u003c\/strong\u003e or \u003cstrong\u003e600 kPa\u003c\/strong\u003e pressure limiting valve to protect the water filter system from extreme water pressure events which could occur in the town water pipes. If your system does not already have a PLV then you should…\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegral dual check valves help prevent backflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiltaMate\u003c\/strong\u003e resists water hammer and limits water pressure to filters thus avoiding costly water damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFMP\u003c\/strong\u003e supplied with fixing clip and screw.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr style=\"margin: 14px 0;\"\u003e\n\u003ch3 style=\"margin-bottom: 6px;\"\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with \u003cstrong\u003eNZS 4608:1992\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAustralian \u003cstrong\u003eWaterMark\u003c\/strong\u003e Approval \u003cstrong\u003eAS1357.2\u003c\/strong\u003e Lic. 02596\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin-bottom: 6px;\"\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eInlet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e¼\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eOutlet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e¼\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e98 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eCheck Valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eDual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eFlow Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e14 L\/min at 700 kPa [100 psi] inlet pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003ePressure Ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e10:1 (for every 10 kPa [1.5 psi] increase in inlet pressure above 1000 kPa [150 psi], the outlet pressure will increase by 1 kPa [0.145 psi])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eOutlet Pressures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e350 and 600 kPa [50, 60 and 85 psi] ± 10% @ 1000 kPa [150 psi] inlet pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMaximum inlet pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1600 kPa [230 psi]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMaximum temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e40 °C [105 °F]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMinimum temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Aqua Blue Filters","offers":[{"title":"Default Title","offer_id":67766976544995,"sku":"FMP350 1\/4\"","price":37.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1249\/4307\/files\/fmp350-350kpa-14-genuine-apex-filtamate-pressure-limiting-valve.jpg?v=1792622922"},{"product_id":"fmbp350-1-2-inlet-1-4-outlet-genuine-apex-filtamate-brass-plastic-pressure-limiting-valve","title":"FMBP350, 350kpa 1\/2\" inlet - 1\/4\" outlet Genuine APEX Filtamate Brass Plastic Pressure Limiting Valve","description":"\u003ch1 align=\"center\"\u003e\u003cimg class=\"entered lazyloaded\" src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/WM_AQUABLUEH2O.png\" alt=\"\" width=\"180\" height=\"181\"\u003e\u003c\/h1\u003e\n\u003ch2 align=\"center\"\u003eAS1357.2 \u0026amp; AS\/NZS2845.1\u003c\/h2\u003e\n\u003ch2 align=\"center\"\u003eLic.WMKA2596\u003c\/h2\u003e\n\u003ch2 align=\"center\"\u003eAPEX Filtamate Brass Plastic Pressure Limiting Valve FMBP-350\u003c\/h2\u003e\n\u003ch2 align=\"center\"\u003e350kPa 1\/2\" BSP brass inlet \/ plastic with 1\/4\" JG outlet port\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModel Identification  \u003c\/strong\u003e\u003cspan id=\"Master_ContentPlaceHolder_rpAttributes_ctl00_lbAttributeValue\"\u003eFMBP350\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel Name  \u003c\/strong\u003e\u003cspan id=\"Master_ContentPlaceHolder_rpAttributes_ctl01_lbAttributeValue\"\u003eFiltamate\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand Name  \u003c\/strong\u003e\u003cspan id=\"Master_ContentPlaceHolder_rpAttributes_ctl02_lbAttributeValue\"\u003eApex\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description  \u003c\/strong\u003e\u003cspan id=\"Master_ContentPlaceHolder_rpAttributes_ctl03_lbAttributeValue\"\u003eDual Check Valve\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type  \u003c\/strong\u003e\u003cspan id=\"Master_ContentPlaceHolder_rpAttributes_ctl04_lbAttributeValue\"\u003eBackflow Prevention Valve\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Size  \u003c\/strong\u003e\u003cspan id=\"Master_ContentPlaceHolder_rpAttributes_ctl05_lbAttributeValue\"\u003eDN15\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Classification  \u003c\/strong\u003e\u003cspan id=\"Master_ContentPlaceHolder_rpAttributes_ctl06_lbAttributeValue\"\u003ePN16\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Classification  \u003c\/strong\u003e\u003cspan id=\"Master_ContentPlaceHolder_rpAttributes_ctl07_lbAttributeValue\"\u003e40°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInlet\/Outlet Designation  \u003c\/strong\u003e\u003cspan id=\"Master_ContentPlaceHolder_rpAttributes_ctl08_lbAttributeValue\"\u003eG1\/2 1\/4 pushfit\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Designation  \u003c\/strong\u003e\u003cspan id=\"Master_ContentPlaceHolder_rpAttributes_ctl09_lbAttributeValue\"\u003eCopper alloy\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccessories or Components  \u003c\/strong\u003eNone\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"heading\" style=\"color: #cc0020; font-weight: bold; font-size: 18px; font-family: arial, helvetica, sans-serif; background-color: #ffffff;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eFilta\u003c\/span\u003e\u003cspan style=\"color: #008000;\"\u003e\u003cem\u003eMate\u003c\/em\u003e\u003c\/span\u003e - Pressure Limiting Valves\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"font-family: arial, helvetica, sans-serif; background-color: #ffffff; width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" align=\"left\" valign=\"top\" width=\"780\"\u003e\n\u003ctable style=\"width: 100%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" colspan=\"5\" width=\"780\"\u003e\u003cimg src=\"http:\/\/www.apexvalves.co.nz\/images\/pixel.gif\" alt=\"\" width=\"1\" height=\"20\" border=\"0\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" align=\"left\" valign=\"top\" width=\"539\"\u003e\n\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold; font-size: 15px;\"\u003eApplication\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eHigh pressure systems to protect downstream components, e.g. Water filters, drink dispensers, ice makers, coffee machines and reverse osmosis machines.\u003c\/li\u003e\n\u003cli\u003eMobile homes and caravans where a connection is available to mains water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold; font-size: 15px;\"\u003eFeatures\/Benefits\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFM \u0026amp; FM 1\/2 are precision machined from high quality NZ brass. FM valve is nickel plated.\u003c\/li\u003e\n\u003cli\u003eIntegral dual check valves help prevent backflow (Not included all models - see specifications and product codes below).\u003c\/li\u003e\n\u003cli\u003eIntegral line strainer protects device and eliminates need for additional strainer to be fitted upstream. (Not included all models - see specifications and product codes below).\u003c\/li\u003e\n\u003cli\u003eFilta\u003cem\u003eMate\u003c\/em\u003e resists water hammer and limits water pressure to filters thus avoiding costly water damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold; font-size: 15px;\"\u003eStandards\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with NZ Building Code G12 (2001)\u003c\/li\u003e\n\u003cli\u003eComplies with NZS 4608:1992\u003c\/li\u003e\n\u003cli\u003eAustralian Watermark Approval AS1357.2 Lic. 02596\u003c\/li\u003e\n\u003cli\u003eAustralian Watermark Approval AS2845.1 Lic. 21876 (FM, FM 1\/2 only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold; font-size: 15px;\"\u003eSpecifications\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"font-size: 13px; margin-left: 0in;\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFM\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003e8mm 1\/4\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003e97mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003eDual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"font-size: 13px; margin-left: 0in;\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFM 1\/2\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"24%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"61%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"24%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"61%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"61%\"\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003eDual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"font-size: 13px; margin-left: 0in;\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMP\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"24%\"\u003eInlet\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"61%\"\u003e1\/4\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"24%\"\u003eOutlet\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"61%\"\u003e1\/4\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"61%\"\u003e98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" valign=\"top\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003eDual (Excludes FMP NZ) - [Available in Imperial pressure ratings without Check Valve - see \u003ca class=\"link\" style=\"color: #cc0020; font-weight: bold; text-decoration: none;\" href=\"http:\/\/www.apexvalves.co.nz\/plumbing\/filtamate\/#imperial\"\u003eImperial Product Codes\u003c\/a\u003e below].\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"font-size: 13px; margin-left: 0in;\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMP 3\/8\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"24%\"\u003eInlet\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"61%\"\u003e3\/8\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"24%\"\u003eOutlet\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"61%\"\u003e3\/8\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"61%\"\u003e110mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003eDual [Available in Imperial pressure ratings without Check Valve - see \u003ca class=\"link\" style=\"color: #cc0020; font-weight: bold; text-decoration: none;\" href=\"http:\/\/www.apexvalves.co.nz\/plumbing\/filtamate\/#imperial\"\u003eImperial Product Codes\u003c\/a\u003e below].\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"font-size: 13px; margin-left: 0in;\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMBP\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"24%\"\u003eInlet\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"61%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"24%\"\u003eOutlet\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"61%\"\u003e1\/4\" John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"61%\"\u003e98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003eDual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"font-size: 13px; margin-left: 0in;\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFM12\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"24%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" valign=\"top\" width=\"24%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"61%\"\u003e12mm John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"24%\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"61%\"\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"font-size: 13px; margin-left: 0in;\" rowspan=\"5\" valign=\"top\" width=\"15%\"\u003eFMSC12\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eInlet:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003e15mm, 1\/2\" BSP (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eOutlet:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003e12mm John Guest connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eLength:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003e107mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eIntegral Line Strainer:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"25%\"\u003eCheck Valve:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" width=\"60%\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"2\" bgcolor=\"#EEEEEE\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"font-size: 13px; margin-left: 0in;\" valign=\"top\" width=\"30%\"\u003eFlow rate:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" valign=\"top\" width=\"70%\"\u003e14 L\/min [4 USgpm] at 700 kPa [100psi] inlet pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"font-size: 13px; margin-left: 0in;\" valign=\"top\" width=\"30%\"\u003ePressure ratio:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" valign=\"top\" width=\"70%\"\u003e10:1 (for every 10 kPa [1.5psi] increase in inlet pressure above 1000 kPa [150psi], the outlet pressure will increase by 1 kPa [0.145psi]).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"font-size: 13px; margin-left: 0in;\" valign=\"top\" width=\"30%\"\u003eOutlet pressures:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" valign=\"top\" width=\"70%\"\u003e350 and 600 kPa [50, 60 and 85psi] +\/- 10% @ 1000 kPa [150psi] inlet pressure (Contact Apex Valves for additional pressures available).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"font-size: 13px; margin-left: 0in;\" valign=\"top\" width=\"30%\"\u003eMaximum inlet pressure:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" valign=\"top\" width=\"70%\"\u003e1600 kPa [230psi]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"font-size: 13px; margin-left: 0in;\" valign=\"top\" width=\"30%\"\u003eMaximum temperature:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" valign=\"top\" width=\"70%\"\u003e40˚C [105˚F]; 60˚C [140˚] for FM and FM 1\/2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tableCaption\" style=\"font-size: 13px; margin-left: 0in;\" valign=\"top\" width=\"30%\"\u003eMinimum temperature:\u003c\/td\u003e\n\u003ctd style=\"font-size: 13px; margin-left: 0in;\" valign=\"top\" width=\"70%\"\u003e1˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eFMP supplied with fixing clip and screw.\u003c\/li\u003e\n\u003cli\u003eFM DR (Dezincification Resistant) brass.\u003c\/li\u003e\n\u003cli\u003eFMP Acetyl plastic.\u003c\/li\u003e\n\u003cli\u003eFMBP DR brass inlet, acetyl plastic outlet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold; font-size: 15px;\"\u003eInstallation\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstallation must be carried out by a Qualified Person.\u003c\/li\u003e\n\u003cli\u003eAll pipe work must be flushed prior to installation.\u003c\/li\u003e\n\u003cli\u003eDo NOT apply heat near valve during installation.\u003c\/li\u003e\n\u003cli\u003eMust be fitted downstream of approved isolating valves.\u003c\/li\u003e\n\u003cli\u003eMust be installed in the direction as indicated by the flow arrow.\u003c\/li\u003e\n\u003cli\u003eMust be protected by a line strainer (See specifications and product codes for valves with integral line strainer).\u003c\/li\u003e\n\u003cli\u003eMust be installed according to local regulations.\u003c\/li\u003e\n\u003cli\u003eMay be fitted in any orientation.\u003c\/li\u003e\n\u003cli\u003eWarranty is limited to any fault found in a valve due to poor workmanship or materials that is returned to Apex Valves Ltd within 1 year from the date of manufacture.\u003c\/li\u003e\n\u003cli\u003eIf thermal expansion (due to heating, cooling) or back pressure can occur downstream, an expansion valve must be fitted to relieve the excessive pressure build up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan class=\"caption\" style=\"color: #333333; font-weight: bold; font-size: 15px;\"\u003eServicing\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Filta\u003cem\u003eMate\u003c\/em\u003e valve opens and closes automatically every time water is drawn through it. As it is a mechanical device we recommend that it is replaced every 5 years or sooner in high usage installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/Filtamate+Pressure+Limiting+Valves-1.jpg\" alt=\"\" width=\"100%\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/Filtamate+Pressure+Limiting+Valves-2.jpg\" alt=\"\" width=\"100%\"\u003e\u003c\/p\u003e\n","brand":"Aqua Blue Filters","offers":[{"title":"Default Title","offer_id":67766976610531,"sku":"FMBP 350 1\/2\" inlet - 1\/4\" outlet","price":65.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1249\/4307\/files\/genuine-apex-filtamate-brass-plastic-pressure-limiting-valve-fmbp-350.jpg?v=1792622924"},{"product_id":"3-8-pressure-limiting-valve-with-single-check-plv-3-8","title":"PLV350 3\/8″ Green Label 350 KPA Pressure Limiting Valve","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch1 align=\"center\"\u003e\u003cimg class=\"entered lazyloaded\" src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/WM_AQUABLUEH2O.png\" alt=\"\" width=\"180\" height=\"181\" data-lazy-src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/WM_AQUABLUEH2O.png\" data-ll-status=\"loaded\"\u003e\u003c\/h1\u003e\n\u003ch2 align=\"center\"\u003eWatermark AS1357.2 Lic 23133\u003cbr\u003e\nNSF : Certified to NSF\/ANSI 61 Section 9\u003c\/h2\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003ch2 style=\"color: #0046ad;text-align: center\"\u003ePressure Limiting Valve 350kPa (50 PSI) Filter Protection Valve\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003ePressure Reduction Valve with \u003cstrong\u003e3\/8\" Quick Connect Push Fit In and Out\u003c\/strong\u003e.\u003cbr\u003e\nSuitable for high pressure systems to protect drink dispensers such as\u003cbr\u003e\nwater filters, ice makers, coffee machines and reverse osmosis machines.\u003cbr\u003e\nPrevents water hammer and back flow.\u003cbr\u003e\n\u003cstrong\u003eAustralian\/New Zealand Watermark Approved\u003c\/strong\u003e\u003cbr\u003e\nHighly recommended when installing water filter systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegral check valve\u003c\/li\u003e\n\u003cli\u003eResists water hammer\u003c\/li\u003e\n\u003cli\u003eStops backflow\u003c\/li\u003e\n\u003cli\u003ePressure limiting valve set at 350 kPa with backflow prevention\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWatermark AS1357.2 Lic 23133\u003c\/li\u003e\n\u003cli\u003eNSF Certified to NSF\/ANSI 61 Section 9\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse;width: 100%;max-width: 600px\" border=\"1\" cellspacing=\"0\" cellpadding=\"6\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth align=\"left\"\u003eLimiting Pressure\u003c\/th\u003e\n\u003ctd\u003e350 kPa (50 PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth align=\"left\"\u003eFlow Rate\u003c\/th\u003e\n\u003ctd\u003e7.5 L\/min at 700 kPa (100 PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth align=\"left\"\u003eMax Pressure\u003c\/th\u003e\n\u003ctd\u003e1600 kPa (230 PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth align=\"left\"\u003eMax Temperature\u003c\/th\u003e\n\u003ctd\u003e4 – 42 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth align=\"left\"\u003eConnections\u003c\/th\u003e\n\u003ctd\u003e3\/8\" John Guest type push-fit tubing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eIdeal for use with \u003cstrong\u003ereverse osmosis filter systems\u003c\/strong\u003e to limit the pressure applied to the system\u003cbr\u003e\nand ensure safe and reliable operation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: x-large\"\u003e\u003cimg src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/Filtamate+Pressure+Limiting+Valves-1.jpg\" alt=\"\" width=\"100%\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: x-large\"\u003e\u003cimg src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/Filtamate+Pressure+Limiting+Valves-2.jpg\" alt=\"\" width=\"100%\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n","brand":"Aqua Blue Filters","offers":[{"title":"Default Title","offer_id":67766986277091,"sku":"PLV350 3\/8\" Green Label 350 KPA","price":24.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1249\/4307\/files\/pressure-limiting-valve-watermark-14-tube-350kpa-50-psi-plv-fmp-350plv350-4_a4b5d096-41bc-4874-92e9-7c240496cc8b.jpg?v=1792623072"},{"product_id":"plv350-1-4-green-label","title":"PLV350 1\/4″ Green Label 350KPA Pressure Limiting Valve","description":"\u003ch1 align=\"center\"\u003e\u003cimg class=\"entered lazyloaded\" src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/WM_AQUABLUEH2O.png\" alt=\"\" width=\"180\" height=\"181\" data-lazy-src=\"https:\/\/waterfilterforfridge.com.au\/img\/cms\/WM_AQUABLUEH2O.png\" data-ll-status=\"loaded\"\u003e\u003c\/h1\u003e\n\u003ch2 align=\"center\"\u003eWatermark AS1357.2 Lic 23133\u003cbr\u003e\nNSF : Certified to NSF\/ANSI 61 Section 9\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuit for Stefani 350kpa Filter Accessory Press Reduce Valve\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReplacing FMP350 \/PLV350 OR FMP 350\u003cbr\u003e\n¼” John Guest Tube Inlet \/ Outlet Connectors\u003cbr\u003e\nEasy to install\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWatermark Certified\u003c\/strong\u003e\u003cbr\u003e\n350kpa water pressure reducing valve\u003cbr\u003e\n- High quality materials\u003cbr\u003e\n- Light weight\u003cbr\u003e\n- Easy installation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures \u0026amp; Benefits\u003c\/strong\u003e\u003cbr\u003e\n- High quality pressure limiting valves being applicated for high pressure system to protect downstream components-Water filters.Drink dispensers RO system.\u003cbr\u003e\n- Protect water filteration devices by limiting water pressure and reducing water hammer.\u003cbr\u003e\n- Different pressure ratio setting for options to suit different application.\u003cbr\u003e\n- Quick fitting connector for easy to install onto your application.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Limiting Valve 350Kpa 50psi Filter Protection Valve\u003c\/strong\u003e\u003cbr\u003e\n- Pressure Reduction Valve with 1\/4\" Quick Connect Push Fit In and Out Suitable for High pressure systems to protect drink dispensers e.g. Water filters, ice makers, coffee machines and reverse osmosis machines. Prevent water hammer and back flow.\u003cbr\u003e\n- \u003cstrong\u003eAustralian\/New Zealand Watermark Approved\u003c\/strong\u003e Highly recommended when installing water filter systems.\u003cbr\u003e\n- Integral Check Valve\u003cbr\u003e\n- Resists water hammer.\u003cbr\u003e\n- Stops backflow.\u003c\/p\u003e\n\u003cp\u003ePressure limiting valve in 350kpa with back flow prevention.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eItem specifics\u003c\/strong\u003e- Power (W): 0\u003cbr\u003e\n- Function: Direct Drink\u003cbr\u003e\n- Water treatment machine Type: Water Purifying Machine\u003cbr\u003e\n- Use: Under Sink\u003cbr\u003e\n- Type: Conditioner\u003cbr\u003e\n- Material: RO Membrane\u003cbr\u003e\n- Voltage (V): 0\u003cbr\u003e\n- Model Number: Z-LV-FPV-0104-40\u003cbr\u003e\n- Color: Light Grey\u003cbr\u003e\n- Water Quality Requirements: Municipal Water\u003cbr\u003e\n- Installation: Kitchen\/Table\u003cbr\u003e\n- Purifying Position: Terminal Purification\u003cbr\u003e\n- Certification: NSF\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003cbr\u003e\n- Watermark AS1357.2 Lic 23133\u003cbr\u003e\n- NSF : Certified to NSF\/ANSI 61 Section 9\u003cbr\u003e\n- Limiting valve: 350kpa (50 PSI)\u003cbr\u003e\n- Flow: 7.5L\/Min at 700 Kpa (100 PSI)\u003cbr\u003e\n- Max Pressure: 1600 Kpa (230 PSI)\u003cbr\u003e\n- Max Temperature: 40ºC (104ºF)\u003cbr\u003e\n- Length:10.5cm\u003cbr\u003e\n- Net Weight:65G\u003cbr\u003e\n- Function description:Protect water purifiers, coffee machine, ice maker and RO pure water machine, water equipment, resist water hammer effect, avoid the filter shell and other equipment damage.\u003c\/p\u003e\n\u003cp\u003eIdeal for a reverse osmosis filter system to limit the pressure applied to the system\u003c\/p\u003e\n","brand":"Aqua Blue Filters","offers":[{"title":"Default Title","offer_id":67766986309859,"sku":"PLV350 1\/4\" Green Label 350KPA","price":24.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1249\/4307\/files\/pressure-limiting-valve-watermark-14-tube-350kpa-50-psi-plv-fmp-350plv350-4_0ec70472-40f5-44b1-9231-74b3650ab93b.jpg?v=1792623073"}],"url":"https:\/\/aquabluefilters.com.au\/collections\/350kpa.oembed","provider":"AQUA BLUE FILTERS ","version":"1.0","type":"link"}